Where is the DIBt approval?
Under Section 16a(2) of the German Model Building Code (worded identically in the state building codes), a general technical approval or type approval is only required for construction methods that deviate substantially from the Technical Building Regulations or for which no generally accepted engineering rules exist. A JUMBO BLOCK structure is precast reinforced concrete construction: designed to DIN EN 1992-1-1, founded to DIN EN 1997-1, concrete to DIN EN 206 and DIN 1045-2 – all adopted Technical Building Regulations. As with any other reinforced concrete structure, the project-specific structural design takes the place of an approval. DIBt approvals do exist for plastic infiltration crates, because no Technical Building Regulation exists for such products.